ORIGINAL ARTICLE
Minerva Dental and Oral Science 2024 April;73(2):96-101
DOI: 10.23736/S2724-6329.23.04788-5
Copyright © 2023 EDIZIONI MINERVA MEDICA
language: English
Effect of photobiomodulation therapy of overprepared dental implant bed on torque removal and implant stability quotient: an experimental study in sheep
Kocher K. XAILANI 1, Shehab A. HAMAD 2 ✉
1 Erbil Health Authority, Erbil, Iraq; 2 Kurdistan Higher Council of Medical Specialties, Erbil, Iraq
BACKGROUND: Primary stability of dental implant is an important prerequisite for achieving osseointegration. This study was conducted to evaluate the effects of photobiomodulation therapy on bone formation-around implants by measuring the implant removal torque and implant stability quotient.
METHODS: This study was conducted in six adult male sheep. Four implants were placed on each side of the lower border of the mandible. The implant beds were prepared to a size of 10 mm in length and 4.8 mm in width, to receive an implant of 8 mm in length and 4 mm in width. Laser application to the socket was performed just before implant placement, and was immediately administered to the surface of the implant and the peri-implant bone before suturing of the wound. The therapy was continued twice daily for the next seven consecutive days. The animals were sacrificed at 4, 8, and 12 weeks, with two animals per time point. The implant-removal torque was determined with an electronic wrench, and the implant stability quotient (ISQ) was assessed with an Ostell device.
RESULTS: The laser treated sides showed significantly higher removal torque and ISQ, at the three-time points (P<0.05). At 4 weeks, the ISQ was 61.44 (±10.4) in the laser group and 48.2 (±16.7) in the control group. At 8 weeks, the ISQ increased to 62.2 (±5.5) in the laser group and 56.1 (±4.3) in the control group. At 12 weeks, the ISQ was 67 (±4.5) in the laser group and 61.875 (±6.3) in the control group. The removal torque at 4 weeks was 218.6 (±62.6) in the laser group and 147.6 (±40.9) in the control group. At 8 weeks, the removal torque increased to 370.5 (±33.3) in the laser group and 250.2 (±25.0) in the control group. At 12 weeks, the removal torque increased to 912.6 (±177.2) in the laser group and 512.1 (±122.6) in the control group.
CONCLUSIONS: Photobiomodulation enhances bone formation and improves implant stability in implants with overzealously prepared oversized implant beds.
KEY WORDS: Dental implants; Low-level light therapy; Osseointegration