Home > Journals > Minerva Anestesiologica > Past Issues > Minerva Anestesiologica 2019 August;85(8) > Minerva Anestesiologica 2019 August;85(8):854-61

CURRENT ISSUE
 

JOURNAL TOOLS

Publishing options
eTOC
To subscribe
Submit an article
Recommend to your librarian
 

ARTICLE TOOLS

Publication history
Reprints
Permissions
Cite this article as
Share

 

ORIGINAL ARTICLE   Free accessfree

Minerva Anestesiologica 2019 August;85(8):854-61

DOI: 10.23736/S0375-9393.19.13246-4

Copyright © 2019 EDIZIONI MINERVA MEDICA

language: English

The effects of ropivacaine 0.0625% and levobupivacaine 0.0625% on uterine and abdominal muscle electromyographic activity during the second stage of labor

Baisong ZHAO 1, Xueya QIAN 2, Qingning WANG 1, Xinxu OU 1, Baohua LIN 2, Xingrong SONG 1

1 Department of Anesthesiology, Guangzhou Women and Children’s Medical Center, Guangzhou Medical University, Guangzhou, China; 2 Department of Obstetrics, Guangzhou Women and Children’s Medical Center, Guangzhou Medical University, Guangzhou, China



BACKGROUND: This study investigated the effect of ropivacaine on uterine and abdominal muscle electromyographic activity during the second stage of labor.
METHODS: A total of 161 patients, including 48 patients receiving 0.0625% ropivacaine for patient-controlled epidural analgesia (PCEA), 64 patients receiving 0.0625% levobupivacaine for PCEA, and 49 patients with no PCEA completed the study. Uterine and abdominal muscle electromyographic activity was continuously recorded from the abdominal surface during the second stage of labor. Maternal demographic and clinical characteristics, maternal and neonatal outcomes, and various electromyographic parameters were recorded.
RESULTS: Second stage of labor was significantly prolonged (P=0.007) for levobupivacaine compared to ropivacaine or no PCEA. The root-mean-square and duration of uterine muscle electromyographic activity was significantly lower for levobupivacaine or ropivacaine compared to no PCEA. The root-mean-square and power of abdominal muscle electromyographic activity was significantly lower for levobupivacaine compared to ropivacaine or no PCEA; the peak frequency of abdominal muscle electromyographic activity was significantly higher for ropivacaine. Visual analogue scale pain scores in patients in the levobupivacaine group or ropivacaine group decreased significantly over time compared to patients in the no PCEA group.
CONCLUSIONS: In conclusion 0.0625% ropivacaine does not suppress abdominal muscle electromyographic activity during the second stage of labor. Maternal and neonatal outcomes were similar in patients receiving ropivacaine or no PCEA.


KEY WORDS: Ropivacaine; Levobupivacaine; Electromyography; Analgesia, epidural; Delivery, obstetric

top of page