Home > Journals > Minerva Medica > Past Issues > Minerva Medica 2020 December;111(6) > Minerva Medica 2020 December;111(6):529-35

CURRENT ISSUE
 

JOURNAL TOOLS

Publishing options
eTOC
To subscribe
Submit an article
Recommend to your librarian
 

ARTICLE TOOLS

Publication history
Reprints
Permissions
Cite this article as
Share

 

ORIGINAL ARTICLE   

Minerva Medica 2020 December;111(6):529-35

DOI: 10.23736/S0026-4806.20.06333-8

Copyright © 2020 EDIZIONI MINERVA MEDICA

language: English

Impact of ultra-long sirolimus-eluting stents on coronary artery lesions: one-year results of real-world FLEX-LONG Study

Vijaya PAMIDIMUKKALA 1, Anurag R. POLAVARAPU 2, Naren R. POLAVARAPU 2, Sirichandana GANGASANI 2, Deepthi GALI 2, Sudheer V. BOLINERA 2, Sravanthi BYRAPANENI 2, Raghava S. POLAVARAPU 3

1 Department of Neurology, Lalitha Super Specialities Hospital Pvt. Ltd., Heart and Brain Center, Kothapet, India; 2 Department of Medicine, Lalitha Super Specialities Hospital Pvt. Ltd., Heart and Brain Center, Kothapet, India; 3 Department of Cardiology, Lalitha Super Specialities Hospital Pvt. Ltd., Heart and Brain Center, Kothapet, India



BACKGROUND: The FLEX-LONG study assessed the safety and clinical outcomes of ultra-long (44 mm/48 mm) biodegradable polymer-coated Supraflex (Sahajanand Medical Technology Pvt. Ltd., Surat, India) sirolimus-eluting stents (SES) in real-world patients with complex, long coronary artery lesions.
METHODS: It was an investigator-initiated, retrospective, non-randomized, observational and single-center study, which evaluated one-year results of 141 patients who had undergone implantation of at least one ultra-long (44 mm/48 mm) Supraflex SES. The incidence of major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR), at one-year follow-up was considered as primary outcome. Stent thrombosis was analyzed as a safety outcome.
RESULTS: The mean age of the study population was 56.2±9.6 years and 78.0% (110/141) patients were male. The study analyzed high risk patients, including 62 (44.0%) hypertensive and 60 (42.6%) diabetic patients. Total 147 target lesions were treated, including 25 (17.0%) total occlusions. Total 51 (34.7%) and 96 (65.3%) Supraflex SES of 44 mm and 48 mm were implanted, respectively. Average stent length and diameter were 46.6±1.9 mm and 3.4±0.2 mm, respectively. One-year follow-up was obtained in 100% of patients. There was one probable stent thrombosis after three weeks. At one-year follow-up, 99.3% of patients remained event free.
CONCLUSIONS: The results of the FLEX-LONG study support the use of ultra-long (44 mm/48 mm) Supraflex SES, in the treatment of high-risk real-world patients. The stent appeared to be safe and effective at one-year with low clinical events in complex, long coronary artery lesions.


KEY WORDS: Drug-eluting stents; Sirolimus; Coronary vessels