Home > Riviste > The Journal of Sports Medicine and Physical Fitness > Fascicoli precedenti > The Journal of Sports Medicine and Physical Fitness 2018 April;58(4) > The Journal of Sports Medicine and Physical Fitness 2018 April;58(4):407-13

ULTIMO FASCICOLO
 

ARTICLE TOOLS

Publication history
Estratti
Per citare questo articolo

THE JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS

Rivista di Medicina, Traumatologia e Psicologia dello Sport


Indexed/Abstracted in: Chemical Abstracts, CINAHL, Current Contents/Clinical Medicine, EMBASE, PubMed/MEDLINE, Science Citation Index Expanded (SciSearch), Scopus
Impact Factor 1,215


eTOC

 

ORIGINAL ARTICLE  EXERCISE PHYSIOLOGY AND BIOMECHANICS


The Journal of Sports Medicine and Physical Fitness 2018 April;58(4):407-13

DOI: 10.23736/S0022-4707.16.06741-4

Copyright © 2016 EDIZIONI MINERVA MEDICA

lingua: Inglese

Validation of non-exhaustive test to determine the aerobic capacity in swimming

Claudio A. GOBATTO 1 , Gustavo GOMES de ARAUJO 1, 2, Vanessa SANTHIAGO 1, Marcelo PAPOTI 3, Fúlvia B. MANCHADO-GOBATTO 1

1 Laboratory of Sports-Applied Physiology, Campinas State University, Limeira, Brazil; 2 Research Group Applied to Sports Science, Federal University of Alagoas, Maceió, Brazil; 3 Sao Paulo University, Monte Alegre, Brazil


PDF  


BACKGROUND: Several methods of aerobic capacity evaluation have been applied to assess and prescribe the training sessions in swimming. However, most protocols either show exhaustive characteristics, triggering transitory stress period or several visits, influencing the session’s organization. Thus, the purpose was to validate a double-bout exercise protocol for non-exhaustive aerobic capacity determination of swimmers.
METHODS: Twelve swimmers were submitted to non-exhaustive and Maximal Lactate Steady State (MLSS) protocols. Non-exhaustive double effort test (NEDE) was performed into 4 sessions with randomized intensities 60-80 s/100 m. Sessions were divided in two bouts with same intensity, duration (180 s) and interval (90 s). Linear interpolation of heart rate difference (∆HR) and lactate difference (∆Lac) enabled determination of a “null” delta. NEDE and MLSS were performed for determination of reproducibility and validity respectively.
RESULTS: The velocity (s/100 m) measured by Δ HR (test 75.16±0.84; retest 74.81±0.75) and ΔLac (test 75.08±0.87; retest 75.14±0.81) did not differ from MLSS (74.00±1.20). Significant correlation was found between test and retest for HR (P=0.001), Lac concentration (P=0.001) and MLSS (HR test P=0.0001; HR retest P=0.0001; Lac test P=0.002; Lac retest P=0.0001).
CONCLUSIONS: In conclusion, non-exhaustive double test evaluated by ΔHR and ΔLac was reproducible and valid to determine the aerobic capacity in swimming.


KEY WORDS: Lactates - Heart rate - Athletic performance - Swimming

inizio pagina

Publication History

Issue published online: March 16, 2018
Article first published online: October 28, 2016
Manuscript accepted: October 18, 2016
Manuscript revised: October 10, 2016
Manuscript received: May 31, 2016

Per citare questo articolo

Gobatto CA, Gomes de Araujo G, Santhiago V, Papoti M, Manchado-Gobatto FB. Validation of non-exhaustive test to determine the aerobic capacity in swimming. J Sports Med Phys Fitness 2018;58:407-13. DOI: 10.23736/S0022-4707.16.06741-4

Corresponding author e-mail

cgobatto@uol.com.br