Home > Riviste > The Journal of Sports Medicine and Physical Fitness > Fascicoli precedenti > The Journal of Sports Medicine and Physical Fitness 2017 May;57(5) > The Journal of Sports Medicine and Physical Fitness 2017 May;57(5):556-64

ULTIMO FASCICOLO
 

JOURNAL TOOLS

eTOC
Per abbonarsi PROMO
Sottometti un articolo
Segnala alla tua biblioteca
 

ARTICLE TOOLS

Publication history
Estratti
Per citare questo articolo

 

ORIGINAL ARTICLE  EXERCISE PHYSIOLOGY AND BIOMECHANICS 

The Journal of Sports Medicine and Physical Fitness 2017 May;57(5):556-64

DOI: 10.23736/S0022-4707.16.06169-7

Copyright © 2016 EDIZIONI MINERVA MEDICA

lingua: Inglese

Critical load: a novel approach to determining a sustainable intensity during resistance exercise

Vivian M., ARAKELIAN 1, 2, Renata G. MENDES 1, Renata TRIMER 1, Flavia C. ROSSI CARUSO 1, Nuno M., de SOUSA 3, Vanessa C. BORGES 3, Camila, do VALLE GOMES GATTO 3, Vilmar BALDISSERA 3, Ross ARENA 4, Audrey BORGHI-SILVA 1, 2

1 Cardiopulmonary Physiotherapy Laboratory, Department of Physiotherapy, Federal University of Sao Carlos, UFSCar, Sao Carlos, Brazil; 2 University of São Paulo, Sao Carlos, Brazil; 3 Laboratory of Exercise Physiology, Department of Physiological Science, Federal University of Sao Carlos, UFSCar, Sao Carlos, Brazil; 4 Department of Physical Therapy and Integrative Physiology Laboratory, College of Applied Health Sciences, University of Illinois, Chicago, IL, USA


PDF


BACKGROUND: A hyperbolic function as well as a linear relationship between power output and time to exhaustion (Tlim) has been consistently observed during dynamic non-resistive exercises. However, little is known about its concept to resistance exercises (RE), which could be defined as critical load (CL). This study aimed to verify the existence of CL during dynamic RE and to verify the number of workbouts necessary to determine the optimal modeling to achieve it.
METHODS: Fifteen healthy men (23±2.5 yrs) completed 1 repetition maximum test (1RM) on a leg press and 3 (60%, 75% and 90% of 1RM) or 4 (+ 30% of 1RM) workbouts protocols to obtain the CL by hyperbolic and linear regression models between Tlim and load performed. Blood lactate and leg fatigue were also measured.
RESULTS: CL was obtained during RE and 3 workbouts protocol estimate it at 53% while 4 tests at 38% of 1 RM. However, based on coefficients of determination, 3 protocols provided a better fit than the 4-parameter model, respectively (R2>0.95 vs. >0.77). Moreover, all intensities increased blood lactate and leg fatigue, however, when corrected by Tlim, were significantly lower at CL.
CONCLUSIONS: It was possible to determinate CL during dynamic lower limbs RE and that 3 exhaustive workbouts can be used to better estimate the CL, constituting a new concept of determining this threshold during dynamic RE and reducing the physically demanding nature of the protocol. These findings may have important applications for functional performance evaluation and prescription of RE programs.


KEY WORDS: Resistance training - Exercise test - Muscle strength

inizio pagina