Home > Riviste > Minerva Urology and Nephrology > Fascicoli precedenti > Minerva Urologica e Nefrologica 2019 December;71(6) > Minerva Urologica e Nefrologica 2019 December;71(6):583-9

ULTIMO FASCICOLO
 

JOURNAL TOOLS

Opzioni di pubblicazione
eTOC
Per abbonarsi
Sottometti un articolo
Segnala alla tua biblioteca
 

ARTICLE TOOLS

Publication history
Estratti
Permessi
Per citare questo articolo
Share

 

ORIGINAL ARTICLE   Free accessfree

Minerva Urologica e Nefrologica 2019 December;71(6):583-9

DOI: 10.23736/S0393-2249.19.03360-5

Copyright © 2019 EDIZIONI MINERVA MEDICA

lingua: Inglese

Smoking reduces PSA accuracy for detection of prostate cancer: results from an Italian cross-sectional study

Cosimo DE NUNZIO , Giorgia TEMA, Alberto TRUCCHI, Antonio CICIONE, Angela SICA, Riccardo LOMBARDO, Andrea TUBARO

Department of Urology, Sant’Andrea Hospital, Sapienza University, Rome, Italy



BACKGROUND: The aim of our study is to evaluate the diagnostic accuracy of prostate-specific antigen (PSA) according to the smoking status in a cohort of European men undergoing prostate biopsy.
METHODS: From 2008 onwards, we consecutively enrolled, at a single institution in Italy, men undergoing 12 core transrectal ultrasound-guided prostate needle biopsy. Demographic, clinical and histopathological data were collected. We excluded men who had PSA >30 ng/mL. Patients were classified in three groups: non-smokers, smokers and former smokers. Receiver-operator characteristics (ROC) curve analysis were used to compare predictive properties of PSA across smoking categories for the final histopathological diagnosis of prostate cancer.
RESULTS: 872 patients were enrolled. with a median age and PSA of 67 years (IQR: 61/74) and 6.2 ng/mL (IQR: 4.4/9.7) respectively.402/872 patients (46%) were non-smokers; 151 of 872 were smokers (17%) and 319 of 872 were former smokers (36%); 374 of 872 (43%) had cancer on biopsy. PSA accuracy for smokers (AUC= 0.47, P=0.490) was lower when compared to non-smokers (AUC=0.59, P=0.003) and former smokers (AUC=0.59, P=0.005).
CONCLUSIONS: In a cohort of Italian men undergoing prostate biopsy, the performance accuracy of PSA, as a predictor of prostate cancer, is lower in smokers. Although the molecular link behind our findings is still unknown, our study firstly showed that the PSA accuracy for PCa diagnosis is significantly influential by smoking.


KEY WORDS: Prostate-specific antigen; Early detection of cancer; Smoking; Prostatic neoplasms

inizio pagina