Home > Riviste > Minerva Cardiology and Angiology > Fascicoli precedenti > Minerva Cardiology and Angiology 2021 August;69(4) > Minerva Cardiology and Angiology 2021 August;69(4):458-63

ULTIMO FASCICOLO
 

JOURNAL TOOLS

eTOC
Per abbonarsi PROMO
Sottometti un articolo
Segnala alla tua biblioteca
 

ARTICLE TOOLS

Publication history
Estratti
Permessi
Per citare questo articolo
Share

 

ORIGINAL ARTICLE   

Minerva Cardiology and Angiology 2021 August;69(4):458-63

DOI: 10.23736/S2724-5683.21.05611-8

Copyright © 2021 EDIZIONI MINERVA MEDICA

lingua: Inglese

Balloon aortic valvuloplasty through the novel transradial technique

Horacio A. MEDINA DE CHAZAL 1 , Ignacio M. SEROPIAN 1, Francisco ROMEO 2, Juan G. CHIABRANDO 1, Juan VALLE RALEIGH 1, Daniel H. BERROCAL 1, Carla R. AGATIELLO 1

1 Department of Interventional Cardiology, Italian Hospital of Buenos Aires, Buenos Aires, Argentina; 2 Icahn School of Medicine at Mount Sinai, Department of Medicine, Mount Sinai St. Luke’s and West, New York, NY, USA



BACKGROUND: Balloon aortic valvuloplasty (BAV) has been typically performed through a femoral approach thus increasing the risk of bleeding and access site-related vascular complications. The aim of this study was to describe the safety and efficacy of transradial aortic valve valvuloplasty (TRBAV).
METHODS: The present research is a retrospective, single-center study including patients undergoing TRBAV (October 2019-July 2020). BAV was performed using 18-25 mm balloons through an 8-10 French (F) radial sheath. Successful BAV was defined as ≥50% reduction in peak-to-peak gradient (efficacy endpoint). Procedural complications, including radial artery occlusion (RAO) at follow-up were evaluated (safety endpoint).
RESULTS: Twenty-four patients underwent TRBAV were included, aged 81 (73-85) years, 70% males, EuroScoreII 3.1 (2.1-5.5). Aortic valve gradient was significantly reduced (pre-50±24 vs. 18.7±13 mmHg post, P<0.001), and 91% had successful BAV. Mean gradient drop was 31.4±16.8 mmHg. One patient (4%) required cross-over to femoral access for severe vasospasm and was excluded from the analysis. Most used sheaths were 8F (46%) and 9F (37%), mostly for 20 mm (50%) and 23 mm (38%) balloons. There were neither major procedural complications (neither balloon entrapment nor compartmental syndrome) nor minor complications (any access-site bleeding). RAO was observed in 2 patients (8%), both asymptomatic.
CONCLUSIONS: TRBAV was safe, feasible, and efficacious with a small rate of conversion and RAO, suggesting reproducibility of this novel technique. TRBAV may represent an alternative to femoral access in selected patients although larger studies are warranted.


KEY WORDS: Aortic valve stenosis; Balloon valvuloplasty; Aorta

inizio pagina