Home > Riviste > The Journal of Cardiovascular Surgery > Fascicoli precedenti > The Journal of Cardiovascular Surgery 2018 December;59(6) > The Journal of Cardiovascular Surgery 2018 December;59(6):797-803

ULTIMO FASCICOLO
 

JOURNAL TOOLS

eTOC
Per abbonarsi PROMO
Sottometti un articolo
Segnala alla tua biblioteca
 

ARTICLE TOOLS

Publication history
Estratti
Per citare questo articolo

 

ORIGINAL ARTICLE  VASCULAR SECTION 

The Journal of Cardiovascular Surgery 2018 December;59(6):797-803

DOI: 10.23736/S0021-9509.16.09207-7

Copyright © 2016 EDIZIONI MINERVA MEDICA

lingua: Inglese

Single-center experience with vascular closure devices in real-world endovascular peripheral interventions

Bruno FREITAS , Sabine STEINER, Yvonne BAUSBACK, Holger STAAB, Daniela BRANZAN, Ursula BANNING‑EICHENSEER, Andrej SCHMIDT, Dierk SCHEINERT

Division of Interventional Angiology, Leipzig University Hospital, Leipzig, Germany


PDF


BACKGROUND: The aim of the current study was to evaluate the efficacy and safety of vascular closure devices (VCDs) in non-cardiac endovascular interventions.
METHODS: Retrospective analysis of consecutive patients submitted to endovascular interventions, with deployment of 2327 vascular closure devices. Demographic, clinical/periprocedural, post-operative, complication and reintervention data were reviewed.
RESULTS: A total of 2107 patients (1409 [66.9%] men) were included. Perclose ProGlide® (Abbott Vascular) was employed 1683 times (72.3%), Angio-Seal™ (St. Jude Medical Inc.) 463 (19.9%) and 181 (7.8%) Exoseal® (Cordis). Patients were 70.4±11 years old. Of all vascular approaches, 1794 were retrograde (77.1%) and 533 antegrade (22.9%), with sheath size ranging from 5 to 8 French. Overall success rate was 95.2% and did not significantly vary according to the device. Overall failure rate was 4.8%, with high puncture site, morbid obesity, previous total anticoagulation and severe calcification being related to worse efficiency results. Major complications occurred in 15 patients (0.6%). All patients were evaluated before discharge from the hospital, and were scheduled to return for ambulatory follow-up visits at 30 days postoperatively. Control duplex ultrasonography was performed on a regular basis, or within this period in case of clinical complain/signs.
CONCLUSIONS: Vascular closure devices proved to be safe and effective in this study. Additional prospective randomized studies are recommended.


KEY WORDS: Vascular closure devices - Endovascular procedures - Hemostasis - Intraoperative complications