Home > Journals > The Journal of Sports Medicine and Physical Fitness > Past Issues > The Journal of Sports Medicine and Physical Fitness 2017 March;57(3) > The Journal of Sports Medicine and Physical Fitness 2017 March;57(3):227-37

CURRENT ISSUE
 

JOURNAL TOOLS

eTOC
To subscribe PROMO
Submit an article
Recommend to your librarian
 

ARTICLE TOOLS

Publication history
Reprints
Permissions
Cite this article as

 

REVIEW  EXERCISE PHYSIOLOGY AND BIOMECHANICS 

The Journal of Sports Medicine and Physical Fitness 2017 March;57(3):227-37

DOI: 10.23736/S0022-4707.16.06049-7

Copyright © 2016 EDIZIONI MINERVA MEDICA

language: English

Portable open-circuit spirometry systems

Brittany S. OVERSTREET 1, David R. BASSETT Jr 1, Scott E. CROUTER 1, Brian C. RIDER 1, Brian B. PARR 2

1 Department of Kinesiology, Recreation, and Sport Studies, University of Tennessee, Knoxville, TN, USA; 2 Department of Exercise and Sports Science, University of South Carolina Aiken, Aiken, SC, USA


PDF


BACKGROUND: The purpose of this review is to describe the evolution of portable open-circuit spirometry systems, and discuss their validity, reliability, and principles of operation.
METHODS: Eleven devices were selected for review: the Oxylog, Aerosport KB1-C, Cosmed K2, Cosmed K4RQ, Cosmed K4b2, MetaMax I, MetaMax II, Metamax3B/VmaxST, Medgraphics VO2000, Oxycon Mobile I and Oxycon Mobile II. The validity (compared to the Douglas bag method [DBM]) and reliability of each device for measuring VO2 was summarized.
RESULTS: Mean differences in resting measurements of VO2 were within ±0.05 L/min for all devices except one (difference of 0.17 L/min). When compared to the DBM, VO2 differences for all devices ranged from 0.01 L/min to 0.29 L/min during submaximal intensity exercise and from 0.01 L/min to 0.36 L/min during vigorous/maximal intensity. During submaximal and maximal intensities, ICC ranged from 0.66-0.99 and CV ranged from 2.0-14.2%. Of these devices, four used breath-by-breath technology and six used micro-proportional sampling technology. Validity and reliability of devices did not seem to differ between methods of gas collection.
CONCLUSIONS: Of the three commercially available devices in 2015, all were found to be reliable. Two of the three systems (Cosmed K4b2 and Oxycon Mobile II) provided valid estimates of VO2 (mean values within ±0.10 L/min of DBM) during rest, and submaximal and maximal intensities, while the MetaMax3B slightly overestimated VO2, particularly at maximal exercise.


KEY WORDS: Oxygen consumption - Indirect calorimetry - Exercise