Home > Journals > Minerva Cardioangiologica > Past Issues > Minerva Cardioangiologica 2017 June;65(3) > Minerva Cardioangiologica 2017 June;65(3):321-30

CURRENT ISSUE
 

ARTICLE TOOLS

Publication history
Reprints
Cite this article as

MINERVA CARDIOANGIOLOGICA

A Journal on Heart and Vascular Diseases


Official Journal of the Italian Society of Angiology and Vascular Pathology
Indexed/Abstracted in: EMBASE, PubMed/MEDLINE, Science Citation Index Expanded (SciSearch), Scopus
Impact Factor 0,695


eTOC

 

REVIEW  


Minerva Cardioangiologica 2017 June;65(3):321-30

DOI: 10.23736/S0026-4725.16.04276-6

Copyright © 2016 EDIZIONI MINERVA MEDICA

language: English

Diagnostic accuracy of intravascular ultrasound-derived minimal lumen area compared with fractional flow reserve

Joao P. LOPES, Michelle K. JORDAN, Hiram BEZERRA, Marco A. COSTA, Guilherme ATTIZZANI

UH Harrington Heart and Vascular Institute, UH University Hospitals Cleveland Medical Center, Cleveland, OH, USA


PDF  


INTRODUCTION: The use of fractional flow reserve (FFR) as the gold standard for functional assessment of intermediate coronary stenosis has been well documented. Intracoronary imaging techniques such as intravascular ultrasound (IVUS) have been used for additional coronary lesion resolution and some of its anatomic parameters have been studied as having possible correlation with FFR, particularly IVUS minimal lumen area (MLA). We performed a comprehensive review of the available literature in the area.
EVIDENCE ACQUISITION: A Pubmed search was performed for all the literature involving comparison of diagnostic accuracy of IVUS-MLA with FFR.
EVIDENCE SYNTHESIS: An extensive description of all the available data regarding IVUS-MLA diagnostic value regarding the FFR of stenotic lesions, for both non-left main (non-LM) and left main (LM) lesions.
CONCLUSIONS: For non-LM lesions IVUS-MLA cutoff values to identify specific FFR thresholds have marked heterogeneity and perform particularly poorly in terms of specificity and positive predictive value. For LM lesions IVUS-MLA performs better and shows a better correlation with FFR, though more data is needed to confirmed that trend.


KEY WORDS: Coronary angiography - Ultrasonography - Myocardial fractional flow reserve - Optical coherence tomography

top of page

Publication History

Issue published online: April 13, 2017
Article first published online: December 14, 2016

Cite this article as

Lopes JP, Jordan MK, Bezerra H, Costa MA, Attizzani G. Diagnostic accuracy of intravascular ultrasound-derived minimal lumen area compared with fractional flow reserve. Minerva Cardioangiol 2017;65:321-30. DOI: 10.23736/S0026-4725.16.04276-6

Corresponding author e-mail

guilherme.attizzani@uhhospitals.org