ORIGINAL ARTICLES
Minerva Cardioangiologica 2012 August;60(4):415-23
Copyright © 2012 EDIZIONI MINERVA MEDICA
language: English
Intracoronary local paclitaxel delivery by X-ray contrast media for in-stent restenosis: a clinical pilot study to assess safety and tolerability
Rutsch W. 1, Scheller B. 2, Borges A. C. 1, Bräutigam M. 3, Clever Y. 2, Cremers B. 2, Dietz U. 4, Richter W. 1, Speck U. 3 ✉
1 HELIOS Klinikum Emil-von-Behring, Berlin, Germany; 2 Department of Internal Medicine III, University of Saarlandes, Saarlandes, Germany; 3 Department of Radiology, Experimental Radiology, Charité – Universitätsmedizin Berlin, Berlin; 4 German Clinic for Diagnostics, Wiesbaden, Germany
AIM:Non-stent-based immediate release formulations of paclitaxel have been shown to reduce in-stent restenosis in animal experiments and clinical trials. In the porcine overstretch model paclitaxel dissolved in the contrast medium iopromide inhibited neointimal proliferation in a dose-dependent manner after intracoronary injection and was well tolerated.
METHODS: As a first step entering clinical development, a phase I trial was performed using four ascending paclitaxel dose/concentration levels: samples of up to 100 mL of the contrast medium (iopromide) containing 10, 50, 100 or 200 µM paclitaxel or iopromide (controls) were randomly administered to patients assigned to bare metal stent implantation for single de novo coronary artery lesions. Safety variables, tolerability and angiographic parameters were assessed.
RESULTS: Adverse events, ECG, systolic and diastolic blood pressure, left ventricular ejection fraction, leukocyte count, other hematological or clinical chemistry data did not reveal any trend which could be related to the study medication. Short-lasting serum paclitaxel concentrations remained significantly below those known from cancer therapy. Angiographic late lumen loss was 0.72±0.50 mm (N.=7) in controls versus 0.45±0.65 mm (N.=17) in all paclitaxel-treated patients; binary restenosis rate was 5/7(63%) versus 6/17 (35%) and target lesion revascularization rate was 4/8 (50%) versus 4/24 (17%).
CONCLUSION: Intracoronary infusion of paclitaxel dissolved in an X-ray contrast medium was well tolerated. The results show restenosis inhibition, but the number of patients examined was too small to demonstrate a statistically significant inhibition.