Home > Journals > > Past Issues > >

CURRENT ISSUE
 

JOURNAL TOOLS

eTOC
To subscribe
Submit an article
Recommend to your librarian
 

ARTICLE TOOLS

Publication history
Reprints
Cite this article as

 

ORIGINAL ARTICLE   Freefree

Minerva Anestesiologica 2018 April;84(4):447-54

DOI: 10.23736/S0375-9393.17.12023-7

Copyright © 2017 EDIZIONI MINERVA MEDICA

language: English

Assessment of rotational thromboelastometry for the prediction of red blood cell requirements in orthotopic liver transplantation

Antoni SABATE 1 , Annabel BLASI 2, Marta COSTA 1, Raquel REYES 1, Joan BELTRAN 2, Ferran TORRES 3, 4

1 Department of Anesthesiology, University Hospital of Bellvitge (IDIBELL), University of Barcelona Health Campus, Barcelona, Spain; 2 Department of Anesthesiology, University Clinical Hospital, IDIBAPS, University of Barcelona Health Campus, Barcelona, Spain; 3 Medical Statistics Core Facility (IDIBAPS), Hospital Clinic, Barcelona, Spain; 4 Unit of Biostatistics, Faculty of Medicine, Autonomous University of Barcelona, Barcelona, Spain


PDF


BACKGROUND: In liver transplantation most studies were designed to predict massive transfusion rather than whether or not transfusion is required. We hypothesized that (presurgery) data from thromboelastometry may predict perioperative blood requirements.
METHODS: A post-hoc analysis of data from a controlled trial was performed with the primary end point of predicting zero red blood cells. Of the 92 patients studied, 6 were excluded because of incomplete EXTEM and/or FIBTEM data. The multivariate models included preoperative variables with a P value <0.10 in the univariate model: age, MELD score, hemoglobin, plasma fibrinogen, platelet count, activated partial thromboplastin time, INR, EXTEM maximum clot amplitude after 10 minutes, EXTEM an FIBTEM maximum clot firmness, plasma creatinine, and donor data.
RESULTS: Blood was transfused to 58% of patients during the surgical procedure and to 34% in the first 24 hours postoperatively. The final model was selected using a backward approach, and fractional polynomials were explored to assess model improvement for the prediction. Hemoglobin was a strong predictor: each 1 g/dL of hemoglobin increase reduced the risk of blood transfusion by 52%. An EXTEM maximum amplitude at 10 min was also a predictor of Red Blood requirement, showing a 64% risk reduction for values between the first quartile (35 mm) and the second quartile (41 mm) but no further improvement for the third and fourth quartiles and resulting in a prediction (ROC AUC of 0.815 [0.771-0.859]).
CONCLUSIONS: Presurgical EXTEM maximum amplitude at 10 min <35 mm is highly predictive of red blood administration during liver transplantation.


KEY WORDS: Thromboelastometry - Blood transfusion - Liver transplantation

top of page