Home > Journals > Gazzetta Medica Italiana Archivio per le Scienze Mediche > Past Issues > Gazzetta Medica Italiana - Archivio per le Scienze Mediche 2020 June;179(6) > Gazzetta Medica Italiana - Archivio per le Scienze Mediche 2020 June;179(6):412-8

CURRENT ISSUE
 

JOURNAL TOOLS

Publishing options
eTOC
To subscribe PROMO
Submit an article
Recommend to your librarian
 

ARTICLE TOOLS

Publication history
Reprints
Permissions
Cite this article as
Share

 

ORIGINAL ARTICLE   

Gazzetta Medica Italiana - Archivio per le Scienze Mediche 2020 June;179(6):412-8

DOI: 10.23736/S0393-3660.19.04118-4

Copyright © 2019 EDIZIONI MINERVA MEDICA

language: English

AQUATITAN™ lower body compression garment results in lower 200-m run timings

Govindasamy BALASEKARAN 1 , Jolene Z. LIM 1, Peggy BOEY 1, Yew C. NG 1, Visvasuresh V. GOVINDASWAMY 2

1 Human Bioenergetics Laboratory, Physical Education and Sports Science, Nanyang Technological University, Singapore; 2 Concordia University Chicago, River Forest, IL, USA



BACKGROUND: AQUATITAN™ compression garments include titanium microparticles that are dissolved in high-function water before being bonded into the fabric. It is unknown if the addition of these particles can provide additional enhancement to sporting performance. The aim of this study was to investigate the effects of AQUATITAN™ lower body compression garment on 50-m, 200-m, and 3000-m running performances.
METHODS: Fifteen recreationally active participants from a university population participated in the study. Three blocks of experimental trials were performed with either AQUATITAN™ lower body compression garment (ATCG) or a placebo-matched compression garment (PCG). Participants performed submaximal and maximal treadmill tests, as well as three outdoor running time trials.
RESULTS: No significant differences were found in all physiological variables, 50-m, and 3000-m timings. However, magnitude-based inferences found likely higher lactate threshold (93.1%), velocity at lactate threshold (79.1%), vVO2max (86.7%), TTE (94.2%), and RERmax (93.9%) values when wearing ATCG compared to PCG. ATCG also had a possibly lower 50-m (73.5%) and 3000-m (61.4%) timing compared to PCG. Significant difference was found (P=0.01) in 200m timings between ATCG and PCG. No significant differences were observed in muscle soreness and creatine kinase variables.
CONCLUSIONS: Performance benefits can be found in wearing AQUATITAN™ compression garment for 200m running events, and the ATCG may have possible advantages over other compression garments. Athletes seeking to gain a performance advantage where an immediate supply of anaerobic energy is needed may consider wearing the AQUATITAN™ lower body compression garment.


KEY WORDS: Athletic performance; Clothing; Running; Exercise; Athletes

top of page