Chirurgia 2011 December;24(6):319-22
Copyright © 2012 EDIZIONI MINERVA MEDICA
language: English
Thoracoscopic resection of a true ectopic mediastinal goiter with intraoperative ultrasound-color Doppler guidance and laparoscopic vessels sealing generator
Gonfiotti A. 1, Jaus M. 1, Barale D. 1, Panconesi R. 2, Bechi P. 2, Macchiarini P. 1
1 Department of General Thoracic and Regenerative Surgery and Intrathoracic Biotransplantation, Careggi University Hospital, Florence, Italy 2 General Surgery, Careggi University Hospital, Florence, Italy
We report a rare case of a true primary mediastinal goiter associated with a papillary thyroid cancer in the cervical gland, located in a difficult para-vascular position (aorto-pulmonary window), and successfully resected through a three ports left thoracoscopy, using the intra-operative ultrasound guidance and the laparoscopic vessel sealing generator.