Pseudoaneurysm of saphenous vein coronary artery bypass graft from a Bentall conduit treated by an hybrid approach

Dell’Amore A., Zanoni S., Noera G.

Department of Cardiovascular and Thoracic Surgery, GVM Hospital for Care and Research, Villa Maria Cecilia, Cotignola, Ravenna, Italy


PDF


Saphenous vein graft pseudo-aneurysm after coronary bypass grafting occurs rarely. Reoperation could be challenging in particular when the pseudo-aneurysm of the proximal vein graft anastomosis happens in patients who had combined replacement of the ascending aorta. We report a case of a patient with a pseudo-aneurysm of the proximal vein graft anastomosis from a modify bentall conduit implanted eight years before treated successfully by a hybrid approach.