Home > Journals > The Journal of Cardiovascular Surgery > Past Issues > Articles online first > The Journal of Cardiovascular Surgery 2019 Mar 21

CURRENT ISSUE
 

JOURNAL TOOLS

eTOC
To subscribe
Submit an article
Recommend to your librarian
 

ARTICLE TOOLS

Publication history
Reprints
Permissions
Cite this article as

 

 

The Journal of Cardiovascular Surgery 2019 Mar 21

DOI: 10.23736/S0021-9509.19.10857-9

Copyright © 2019 EDIZIONI MINERVA MEDICA

language: English

Mid-term outcomes of endovascular aneurysm repair in challenging aortic neck anatomy based on experience from the GREAT C3 registry

Tamer SAYED , Ahmed EL BASTY, Diane HILDEBRAND, Paul BACHOO, on behalf of the GREAT European C3 Module Investigators

Department of Vascular and Endovascular Surgery, Aberdeen Royal Infirmary, Aberdeen, UK


PDF


BACKGROUND: The European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT) evaluates the outcome and deployment mechanism of the C3 Gore Excluder stent-graft. We aimed to assess the mid- to long-term durability of the C3 Gore Excluder stent-graft in the management of challenging aortic neck morphology, outside the instruction of use (IFU).
METHODS: The prospectively collected data from GREAT were retrospectively analysed. For each subject demographic, pre/intra- and postoperative variables were collected. The main outcomes measured were serious adverse events (device-related, cerebrovascular, cardiac, pulmonary, pulmonary embolism, limb ischemia, and renal complications) and re-intervention at the 6-year follow-up. In this study, outside IFU was defined as aortic neck length <15 mm and/or aortic neck angle >60°.
RESULTS: A total of 399 subjects (86.7% male, mean age 73.9 years) were identified. Sixty-eight subjects (17%) from 11 recruiting sites underwent endovascular aneurysm repair (EVAR) outside IFU, and 399 devices were implanted. Of these, 47% had neck length <15 mm, 72.3% had neck angulation > 60°, and 21% had both. Mean follow-up duration was 53.5 months (SD=22.3). At the 6-year follow- up, the group with challenging anatomy required significantly more re-interventions (23.5% vs. 13.3%, p<0.05) and reported more serious adverse events (42.6% vs. 30.6%, P<0.005) than those within IFU.
CONCLUSIONS: Midterm outcomes of the C3 Gore Excluder stent-graft are safe and effective within IFU. Outside IFU patients required significantly more all or device related re-interventions; however, they did not sustain significantly more serious adverse events.


KEY WORDS: Endovascular aneurysm repair - Challenging aortic neck - GREAT C3 Registry

top of page