The Journal of Cardiovascular Surgery 2017 December;58(6):916-30

DOI: 10.23736/S0021-9509.17.09920-7

Copyright © 2017 EDIZIONI MINERVA MEDICA

language: English

Patterns of use and durability for the Mitroflow aortic valve: a systematic review of the literature

Theodor FISCHLEIN 1, Steffen PFEIFFER 1, Vincenzo BAGNARDI 2, Giuseppe SANTARPINO 1

1 Department of Cardiac Surgery, Klinikum Nürnberg, Paracelsus Medical University, Nuremberg, Germany; 2 Department of Statistics and Quantitative Methods, University of Milan-Bicocca, Milan, Italy


PDF  


INTRODUCTION: The aim of this study was to evaluate durability of Mitroflow and patterns of use compared with other aortic valves through a systematic review of the literature.
EVIDENCE ACQUISITION: A total of 52 papers that included 33,630 patients met eligibility requirements that allowed summary statistical information to be determined regarding structural valve degeneration risk.
EVIDENCE SYNTHESIS: Mitroflow has been disporportionately implanted in patients to be at higher risk for structural valve degeneration.
CONCLUSIONS: Since Mitroflow valves were implanted more often in these high-risk patients, it was impossible to distinguish the effects of valve size or gender from valve type on structural valve degeneration risk.


KEY WORDS: Transcatheter aortic valve replacement - Bioprosthesis - Meta-analysis

top of page

Publication History

Issue published online: September 14, 2017
Article first published online: May 26, 2017
Manuscript accepted: May 25, 2017
Manuscript revised: April 26, 2017
Manuscript received: February 18, 2017

Cite this article as

Fischlein T, Pfeiffer S, Bagnardi V, Santarpino G. Patterns of use and durability for the Mitroflow aortic valve: a systematic review of the literature. J Cardiovasc Surg 2017;58:916-30. DOI: 10.23736/S0021-9509.17.09920-7

Corresponding author e-mail

g.santarpino@libero.it