Ricerca avanzata

Home > Riviste > The Journal of Sports Medicine and Physical Fitness > Fascicoli precedenti > The Journal of Sports Medicine and Physical Fitness 2015 Ottobre;55(10) > The Journal of Sports Medicine and Physical Fitness 2015 Ottobre;55(10):1129-37

FASCICOLI E ARTICOLI   I PIÙ LETTI   eTOC

ULTIMO FASCICOLOTHE JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS

Rivista di Medicina, Traumatologia e Psicologia dello Sport

Indexed/Abstracted in: Chemical Abstracts, CINAHL, Current Contents/Clinical Medicine, EMBASE, PubMed/MEDLINE, Science Citation Index Expanded (SciSearch), Scopus
Impact Factor 1,111

Periodicità: Mensile

ISSN 0022-4707

Online ISSN 1827-1928

 

The Journal of Sports Medicine and Physical Fitness 2015 Ottobre;55(10):1129-37

EXERCISE PHYSIOLOGY AND BIOMECHANICS 

 ORIGINAL ARTICLES

Reliability of the assessment of peripheral muscle fatigue induced by high-intensity intermittent exercise

Rampinini E. 1, 2, Connolly D. R. 1, Oppici L. 1, Alberti G. 2, La Torre A. 2, Bosio A. 1

1 Human Performance Laboratory, MAPEI Sport Research Centre, Olgiate Olona, Varese, Italy;
2 Department of Sport, Nutrition and Health Sciences, Faculty of Exercise Sciences, Università degli Studi di Milano, Milan, Italy

AIM: Reliability of the assessment of peripheral fatigue induced in knee extensors by high-intensity intermittent running exercise (HIE) was established in ten amateur soccer players (age: 18±1, height: 178±5 cm, weight: 68±8 kg).
METHODS: Transcutaneous electrical stimulations before and after HIE determined muscle contractile properties on three separate occasions (T1, T2 and T3), each separated by 7 days.
RESULTS: No significant differences were noted for any of the parameters measured (P=0.101). The ICC values for peak torque (PT) varied from moderate to high, with the exception of PT at 10-Hz calculated comparing T2 vs. T1 (range PRE=0.78-0.92; POST=0.76-0.97). The ICC derived from PT percentage decrements data were all low, with the exception of PT decrements at 1 Hz calculated comparing T3 vs. T2 (ICC=0.85, moderate). The TE for all contractile parameters obtained using 1-Hz and 100-Hz electrical stimulations were below 10%, including some that demonstrated a TE lower than 5%. Muscle contractile properties determined using 10-Hz stimulations showed a higher level of TE (range: 3.2-15.1%). Similar results were obtained for maximal rate of torque development and torque relaxation.
CONCLUSION: From the results of this study it can be concluded that muscle contractile properties express a good level of reliability in baseline and postexercise measures following familiarization.

lingua: Inglese


FULL TEXT  ESTRATTI

inizio pagina