Home > Riviste > Minerva Cardioangiologica > Fascicoli precedenti > Minerva Cardioangiologica 2016 Febbraio;64(1) > Minerva Cardioangiologica 2016 Febbraio;64(1):15-22

ULTIMO FASCICOLO
 

ARTICLE TOOLS

Estratti

MINERVA CARDIOANGIOLOGICA

Rivista sulle Malattie del Cuore e dei Vasi


Official Journal of the Italian Society of Angiology and Vascular Pathology
Indexed/Abstracted in: EMBASE, PubMed/MEDLINE, Science Citation Index Expanded (SciSearch), Scopus
Impact Factor 0,752


eTOC

 

ORIGINAL ARTICLES  


Minerva Cardioangiologica 2016 Febbraio;64(1):15-22

lingua: Inglese

Paclitaxel-coated balloon angioplasty for de novo coronary lesions: a long- term follow-up study

Javier BENEZET, Alejandro GUTIÉRREZ-BARRIOS, Antonio AGARRADO, Sergio GAMAZA, Dolores RUIZ-FERNÁNDEZ, Ana DEL RÍO, Jesús ONETO

Department of Cardiology, Hospital de Jerez de la Frontera, Jerez de la Frontera, Cádiz, Spain


PDF  


BACKGROUND: Paclitaxel-coated balloons (PCB) have been demonstrated to be successful for the treatment of in-stent restenosis. Although their role in the treatment of de novo lesions has not been fully clarified, they are often used for this indication. This prospective study evaluated the long-term efficacy and safety of the SeQuent® Please PCB (B. Braun, Melsungen, Germany) angioplasty for de novo coronary lesions in routine real-world practice.
METHODS: Between January 2010 and January 2012, all consecutive patients with de novo coronary lesions treated with the SeQuent® Please PCB at our institution were included. The primary endpoint was the clinically driven target lesion revascularization (TLR) rate at 36 months. The secondary endpoint was the rate of major adverse cardiac events (MACE: cardiac death, myocardial infarction [MI], and TLR).
RESULTS: Fifty-three patients with 56 lesions were included. The mean reference vessel diameter was 2.4±0.4 mm and the mean target lesion length was 18.1±6.2 mm. Procedural success was 98.2%. Coronary dissection occurred in 7 patients (12.5 %) and no vessel thrombosis was documented. Additional BMS was implanted in 14 target lesions (25 %). Follow-up rate was 94.3 %. The TLR rate at 36 months was 5.4 %. The MACE rate was 8.9 %, with 1.8 % cardiac death and 3.6 % MI.
CONCLUSIONS: Treatment of de novo coronary lesions with the SeQuent® Please PCB provides good clinical outcomes demonstrated by the low TLR rate and low MACE rates at long-term follow-up.