Ricerca avanzata

Home > Riviste > Minerva Cardioangiologica > Fascicoli precedenti > Minerva Cardioangiologica 2014 Dicembre;62(6) > Minerva Cardioangiologica 2014 Dicembre;62(6):449-59

FASCICOLI E ARTICOLI   I PIÙ LETTI   eTOC

ULTIMO FASCICOLOMINERVA CARDIOANGIOLOGICA

Rivista sulle Malattie del Cuore e dei Vasi

Official Journal of the Italian Society of Angiology and Vascular Pathology
Indexed/Abstracted in: EMBASE, PubMed/MEDLINE, Science Citation Index Expanded (SciSearch), Scopus
Impact Factor 0,752

Periodicità: Bimestrale

ISSN 0026-4725

Online ISSN 1827-1618

 

Minerva Cardioangiologica 2014 Dicembre;62(6):449-59

 ARTICOLI ORIGINALI

Non-invasive hemodynamic analysis in cardiac resynchronization therapy patients wearing quadripolar left ventricular leads: the importance of pacing electrode selection

Santini L. 1, Legramante J. M. 2, Condemi F. 1, Santucci L. 2, Panattoni M. G. 1, Crobeddu P. 2, Sergi D. 1, Forleo G. B. 1, Romeo F. 1

1 Department of Cardiology, Tor Vergata University, Rome, Italy;
2 Department of Emergency, Tor Vergata University, Rome, Italy

AIM: Quadripolar left ventricular (LV) leads offer multiple choices for LV pacing increasing programming flexibility. Aim of this study is to assess the influence of LV pacing vector selection on hemodynamic parameters for patients who underwent cardiac resynchronization therapy (CRT) using quadripolar LV lead chronically evaluated with a non-invasive approach by Nexfin® system provided analysis (BMEYE B.V., Amsterdam, The Netherlands).
METHODS AND RESULTS: In 16 CRT patients implanted with a quadripolar LV lead (mean follow-up 8,8 ±13,4 months after implantation), we measured Cardiac Output (CO), Mean Blood Pressure (MBP), Total Peripheral Resistance (TPR), LV dP/dt max and Stroke volume (SV) from each one of the ten available bipolar pacing configurations. All the recorded parameters showed marked differences among the ten pacing configurations, but dP/dt max, SV and TPR were those showing the wider range, depending of the selected pacing vector. The average delta for the whole group of subjects between the maximum and minimum hemodynamic values for each pacing configuration were 15.9% for SV, 21.1% for dP/dt max and 20.3% for TPR. Inter-individual analysis of data failed to identify a link between a specific pacing vector and the hemodynamic response.
CONCLUSION: Our study demonstrates that different bipolar pacing configurations, even if arising from a single CS branch, substantially modify the hemodynamic effect of LV pacing in CRT patients. Moreover, the non-invasive hemodynamic analysis suggests the better pacing configuration should be established individually and could represent an important issue in optimizing CRT during follow-up.

lingua: Inglese


FULL TEXT  ESTRATTI

inizio pagina