Advanced Search

Home > Journals > Italian Journal of Vascular and Endovascular Surgery > Past Issues > Italian Journal of Vascular and Endovascular Surgery 2007 June;14(2) > Italian Journal of Vascular and Endovascular Surgery 2007 June;14(2):97-102



A Journal on Vascular and Endovascular Surgery

Official Journal of the Italian Society of Vascular and Endovascular Surgery
Indexed/Abstracted in: EMBASE, Scopus

Frequency: Quarterly

ISSN 1824-4777

Online ISSN 1827-1847


Italian Journal of Vascular and Endovascular Surgery 2007 June;14(2):97-102


Diffusion-weighted magnetic resonance imaging after carotid artery stenting: a systematic review of the literature

Kastrup A., Gröschel K., Schnaudigel S.

Department of Neurology University of Göttingen, Göttingen, Germany

Carotid angioplasty and stenting (CAS) is currently being evaluated as an alternative treatment modality to carotid endarterectomy (CEA) in patients with severe carotid artery stenosis. At present, diffusion-weighted MR-imaging (DWI) is the most sensitive tool to detect early cerebral ischemia and offers the possibility of visualizing even small embolic lesions shortly after their emergence. Thus, DWI is increasingly being used as a surrogate marker of thromboembolic events after either CEA or CAS. The purpose of this article is to discuss the potential application of DWI in patients undergoing CAS in the context of the literature and own works within this field. To date, 19 studies have used DWI to determine the occurrence of cerebral ischemia after CAS and found new lesions in 9% to 64% of the patients. The majority of these lesions were clinically asymptomatic and of less than 10 mm in diameter. So far, the reported values of the incidence of new DWI lesions after CAS vary greatly and most likely reflect differences in patient characteristics, experience of the interventionalist, sensitivity of the DWI techniques in detecting small lesions, as well as in the time-point of imaging after CAS. Another variable may be the differential usage of cerebral protection devices in particular because evidence is accumulating that the use of cerebral protection devices potentially reduces the number of new ipsilateral DWI lesions after CAS. Although it is beyond doubt that DWI is a useful quality assessment tool, which is also able to improve the safety of CAS, further research is needed to clarify the impact of new DWI lesions on brain structures as well as cognitive brain functions.

language: English


top of page