Advanced Search

Home > Journals > Minerva Ginecologica > Past Issues > Minerva Ginecologica 2015 February;67(1) > Minerva Ginecologica 2015 February;67(1):65-79

ISSUES AND ARTICLES   MOST READ   eTOC

CURRENT ISSUEMINERVA GINECOLOGICA

A Journal on Obstetrics and Gynecology

Indexed/Abstracted in: EMBASE, PubMed/MEDLINE, Scopus, Emerging Sources Citation Index

Frequency: Bi-Monthly

ISSN 0026-4784

Online ISSN 1827-1650

 

Minerva Ginecologica 2015 February;67(1):65-79

ADVANCES IN GYNECOLOGY AND OBSTETRICS (PART I) 

Intrapartum fetal heart rate monitoring interpretation in labour: a critical appraisal

Maso G. 1, Piccoli M. 1, De Seta F. 2, Parolin S. 1, Banco R. 1, Camacho Mattos L. 1, Bogatti P. 1, Alberico S. 1

1 Department of Obstetrics and Gynecology, Institute for Maternal and Child Health, IRCCS Burlo Garofolo, Trieste, Italy;
2 Department of Obstetrics and Gynecology, Institute for Maternal and Child Health, IRCCS Burlo Garofolo, University of Trieste, Trieste, Italy

Electronic fetal monitoring (EFM) has been introduced in the obstetrics practice as a test to identify the first signs of fetal deterioration, allowing a prompt intervention to reduce neonatal morbidity and mortality. However, results from clinical trials fail to demonstrate a clear benefit with the use of EFM. No decrease in the incidence of cerebral palsy due to intrapartum asphyxia has been achieved and a significant increase in the rate of operative deliveries and in medico-legal litigations has been observed instead. Despite the lack of evidence supporting its safety and effectiveness, this method is routinely used in the clinical practice and periodical updated guidelines to standardize the method of interpretation and proper actions are proposed. However, limitations still exist and the unavoidable consequences are the increasing rate of caesarean delivery, partly due to a defensive attitude in medical choices, and medico-legal litigations for presumed inappropriate evaluation in case of perinatal adverse event. While Obstetrics Societies are trying to “fight” the rise in caesarean section rates, intrapartum EFM tracings are taken in the court proceedings as one of the main evidences in case of adverse event. The aim of this review is to discuss the limitations of guidelines dealing with intrapartum EFM and the pathophysiological basis to assess the suspicious tracings which represent the most observed and critical issue of EFM interpretation.

language: English


FULL TEXT  REPRINTS

top of page