Home > Journals > European Journal of Physical and Rehabilitation Medicine > Past Issues > Articles online first > European Journal of Physical and Rehabilitation Medicine 2016 Jan 15

CURRENT ISSUE
 

ARTICLE TOOLS

Reprints

EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE

A Journal on Physical Medicine and Rehabilitation after Pathological Events


Official Journal of the Italian Society of Physical and Rehabilitation Medicine (SIMFER), European Society of Physical and Rehabilitation Medicine (ESPRM), European Union of Medical Specialists - Physical and Rehabilitation Medicine Section (UEMS-PRM), Mediterranean Forum of Physical and Rehabilitation Medicine (MFPRM), Hellenic Society of Physical and Rehabilitation Medicine (EEFIAP)
In association with International Society of Physical and Rehabilitation Medicine (ISPRM)
Indexed/Abstracted in: CINAHL, Current Contents/Clinical Medicine, EMBASE, PubMed/MEDLINE, Science Citation Index Expanded (SciSearch), Scopus
Impact Factor 2,063


eTOC

 

European Journal of Physical and Rehabilitation Medicine 2016 Jan 15

Copyright © 2016 EDIZIONI MINERVA MEDICA

language: English

Patient- specific interface pressure case study at transradial prosthetic socket: comparison trials between ICRC polypropylene socket and air splint socket

Nasrul A. ABD RAZAK, Noor Azuan ABU OSMAN, Sadeeq A. ALI, Hossein GHOLIZADEH

Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia


FULL TEXT  


BACKGROUND: While considering how important the interface between the amputees with the prostheses socket, we have carried out research to compare the gradient pressure occur at the interface socket that may lead to the discomforting effects to the user using common ICRC polypropylene socket and air splint socket.
DESIGN: Not Applicable.
SETTING: Not Applicable.
POPULATION: The subject was a 23 year old who suffered a traumatic defect on the right arm caused by higher electrical volt.
METHODS: F-Socket sensors have been used to measure dynamic socket interface pressure for the transradial amputee wearer during static and dynamic movements. The printed circuit with a thickness of 0.18 mm is equipped between the socket and the surface of the residual limb. Two F-Socket sensor is required to cover the entire socket surface attached to the residual limb. The average of 10 trials made on prosthetic user using both type of sockets for static and dynamic movements was recorded.
RESULTS: The pressure gradient shows that the circumference of the socket interface for the ICRC polypropylene socket gives the most pressure distributions to the amputees compared to the pressure gradient for the air splint socket.
CONCLUSION: The pressure gradient for ICRC socket increased consistently when the user makes movements while for the air splint socket remain constantly.
CLINICAL REHABILITATION IMPACT: The specific interface pressure occur at the socket interface help in determine the comfort and pain of the socket design and improve the correlation between the user and the prosthesis.

top of page

Publication History

Cite this article as

Corresponding author e-mail

nasrul.anuar@um.edu.my